ANALISIS LOSSES KAPASITAS KETIDAKSEIMBANGAN DAYA BEBAN PADA TRANSFORMATOR DISTRIBUSI MENGGUNAKAN SIMULASI ETAP
Abstract
hen loading a transformer, it can be expected that the value of the loading will not exceed the set standard, namely 80%. When loading a transformer, it can also be expected that the loading values for each phase (R, S, and T) are balanced. However, if there is a load imbalance, it cannot exceed 25%. This results in the impact of the load imbalance resulting in a neutral conductor current and this neutral current will occur losses . The next stage is collecting data from the field related to the discussion that will be discussed. This data was obtained from one of the distribution transformers with a capacity of 2500 KVA belonging to PT. Shoe Manufacturing, the next stage is to calculate and simulate losses and load imbalance with neutral current using ETAP 12.6 software on the transformer. In the calculations and simulations it will later be used as a basic benchmark regarding load analysis on the transformer. Based on the calculations that have been carried out, a percentage of 4% can be obtained and the lowest is at night, namely 2 %. So that the load on the transformer can be balanced, load balancing can be done on each phase of the transformer. The peak load on the transformer occurs in the afternoon where the percentage is 30.9%. And the lowest occurred at night at 22.15%. However, power losses are greater in the afternoon compared to the evening, namely 85.35KW
Keywords
Full Text:
PDFReferences
Dennis Satria Wahyu Jayabadi*), B. W. and M. F. (n.d.). Analisis Ketidakseimbangan Beban Trafo 1 Gi Srondol Terhadap Rugi-Rugi Akibat Arus Netral Dan Suhu Trafo Menggunakan Etap 12.6.0.
Gamma Ayu Kartika Sari. (n.d.). Analisa Pengaruh Ketidakseimbangan Beban Terhadap Arus Netral Dan Losses Pada Trafo Distribusi Studi Kasus Pada Pt. Pln (Persero) Rayon Blora.
Jamil, R., Dame, R., Wibowo, H., Syahruddin, M., Listrik, T., Elektro, T., & Medan, P.
N. (n.d.). Implementasi Penggunaan Software Etap 12.6 Untuk Analisis Pembebanan Pada Transformator Distribusi 2000 Kva.
Latupeirissa, H. L. (n.d.). Pengaruh Ketidakseimbangan Beban Terhadap Arus Netral dan
Losses Daya Pada Trafo Distribusi. JURNAL SIMETRIK, 2017.
Nirwana, D., Fitri Kuraisy, A., Yusan Naim, M., Jaya, A., & Studi Teknik Elektro, P. (2020). Analisis Rugi-Rugi Daya Pada Jaringan Distribusi Penyulang Jentak Di Ulp Jeneponto PT PLN (Persero) Sulselrabar. 3(1), 19–24.
Putranto Jati. (n.d.). Analisa Ketidakseimbangan Beban Terhadap Arus Netral Pada Trafo 30 Mva Gardu Induk 150/20 Kv Purwodadi.
Rahayu dwi Lestari. (n.d.). Analisis Pengaruh Ketidakseimbangan Beban Transformator 3 Phase Terhadap Susut Daya pada jaringan distribusi PT. PLN (Persero) ULP Manahan. Rahayu Dwi Lestari, 1–24.
Samsinar, R., & Wiyono, W. (n.d.). Studi Keandalan Rekonfigurasi Jaringan Program Zero Down Time (Zdt) di Kawasan Sudirman Central Business Distric (Scbd) Menggunakan Software ETAP 12.6.
Tiko Arjanati Putra. (n.d.). Analisis Pengaruh Ketidakseimbangan Beban Dan Suhu Eksternal Terhadap Susut Umur Transformator.
zainal syaroni. (2019). Analisis Ketidakseimbangan Beban Transformator Distribusi 20 Kv Dan Solusinya Pada Jaringan Tegangan Rendah. Zainal Syaroni, 1–8
DOI: http://dx.doi.org/10.31000/jte.v9i1.13872
Article Metrics
Abstract - 146 PDF - 70Refbacks
- There are currently no refbacks.
Copyright (c) 2025 Jurnal Teknik Elektro

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
CURRENT INDEXING JTE
![]() |
![]() |
![]() |
![]() |
![]() |
|
------------------------------------------------------------------------------------------------------------------------------------------------