Technical Study of Arresters in the 20 KV Distribution Network at PT. PLN RAYON TANDES
DOI:
https://doi.org/10.31000/jte.v8i2.13864Keywords:
Control System, Transformer, ArresterAbstract
Arrester is a device in an electrical system that will protect electrical equipment caused by lightning. Study the characteristics of lightning rods so you can see their performance in protecting transformers during lightning surges. Pay attention to the factors that will influence the voltage and surge current, the distance of the lightning protection, the slope of the incident wave, the speed of the surge wave, and the basic insulation level. The level of failure to protect against lightning occurs because of the basic insulation level of the device and the location of the lightning protection device, in calculating the voltage value. The nominal lightning rod is installed continuously on the lightning rod without affecting its operating characteristics. The rated voltage value of the lightning rod is 22 kV, the rated voltage of the 20 kV lightning rod is 24 kV in the distribution network and the protection factor value is the lightning protection level. After making the protection level value 95.7 kV, the protection factor value with the TID of the 125 kV transformer is determined. The protection factor value is 23.44, the protection factor value is 20% higher than the tolerance factor.
References
Syakur, A., Warsito, A., & Nilawati, L. (2009). Kinerja arrester akibat induksi sambaran petir pada jaringan tegangan menengah 20 kV. Transmisi: Jurnal Teknik Elektro, 11(1), 9-14.
Putra, C. N., Tasmono, H., & Wardah, I. A. (2022). Analisa kejenuhan dan burden transformator arus penyulang 20kV gardu induk Rungkut trafo 4. Prosiding Senakama, 1, 585-594.
Noufanda, Y. F., Slamet, P., Basyarach, N. A., Ridhoi, A., & Prenata, G. D. (2021). Keandalan sistem jaringan distribusi 20KV di PT. PLN Rayon Ploso menggunakan metode FMEA. ElSains.JurnalElektro, 3(2), 53-60.
https://doi.org/10.30996/elsains.v3i2.5990
Dasweptia, D., Hamdani, A. S., & Kurniawan, T. (2022). Pengaruh penempatan lightning arrester sebelum dan sesudah fuse cut out terhadap tegangan lebih pada transformator distribusi 20 kV di PT. PLN (Persero) Rayon Tanjung Karang. Jurnal Ilmiah Teknik Elektro, 4(1), 18-22. https://doi.org/10.36269/jtr.v4i1.988
Widagdo, R. S., & Andriawan, A. H. (2023). Prediction of age loss on 160 KVA transformer PT. PLN ULP Kenjeran Surabaya using the linear regression method. Jurnal Riset Rekayasa Elektro, 5(2), 83. https://doi.org/10.30595/jrre.v5i2.18140
Tondok, Y. P., Patras, L. S., & Lisi, F. (2019). Perencanaan transformator distribusi 125 kVA. Jurnal Teknik Elektro dan Komputer, 8(2), 83-92.
Darsono, D., Suyamto, S., & Taufik, T. (2016). Analisis efisiensi trafo frekuensi tinggi pada sumber tegangan tinggi Cockcroft Walton MBE lateks. Ganendra: Majalah IPTEK Nuklir, 17(2), 101. https://doi.org/10.17146/gnd.2014.17.2.2815.
Afriyan, V., Wardani, A. L., & Budiono, G. B. G. (2021). Analisa pembebanan transformator di PT. Henson Farma. El Sains: Jurnal Elektro, 2(2), 45-52.
https://doi.org/10.30996/elsains.v2i2.4772
Rinas, I. W. (2013). Studi analisis arrester dan derating akibat pengaruh THD pada gardu transformator daya di Fakultas Teknik Universitas Udayana. Majalah Ilmiah Teknologi Elektro, 11(1).
SPLN D5.003. (2013). Pedoman pemilihan arrester untuk jaringan distribusi 20kV.
Bhaskara, I. K. A. Y., Arjana, I. G. D., & Suartika, I. M. (2019). Analisa kegagalan lightning arrester pada penyulang Sulahan Bangli. Spektrum, 6(3), 94-100.
Andriawan, D. (2014). Kinerja arrester yang sudah berusia lebih dari 10 tahun di gardu induk 150 KV Ungaran - Semarang. Jurnal Teknik Elektro, 6(2). https://doi.org/10.15294/jte.v6i2.3582
Rusdjaja, T. (2013). Buku pedoman pemeliharaan lightning arrester (LA), 7(2). Naibaho, N. (2017). Analisa sistem pentanahan elektroda ROD, 67.
Romadona, B. (2018). Hubungan arus arrester terhadap suhu di GI Wonogiri
Downloads
Published
Issue
Section
License
The conditions that must be fulfilled by the author are as follows:- The author retains copyright and grants the journal the right of first publication of the manuscript simultaneously with the license below Creative Commons Attribution License which allows others to share the work with a statement of authorship of the work and initial publication in this journal.
- Authors may enter into separate additional contractual arrangements for the non-exclusive distribution of rich versions of journal publications (e.g. posting them to an institutional repository or publishing them in a book), with acknowledgment of their initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g. in institutional repositories or on their websites) before and during the submission process, as this can lead to productive exchange, as can earlier and greater citations of the published work. (cek Open Access Effects).