Analisis Coeffisient Of Peformance (COP) Dan Energy Efficiency Ratio (EER) Pada AC Split Inverter Kapasitas ½ PK Dengan Menggunakan Freon R-22 dan Freon R-32
DOI:
https://doi.org/10.31000/mbjtm.v7i1.8691Keywords:
Inverter Split Air Conditioner, COP, EER, Refrigerant, R-22, R-32.Abstract
Air conditioner (AC) is a tool used to condition the air in a room or product temperature. Air conditioning in the form of regulating temperature, regulating cleanliness, and adjusting the air flow rate. The purpose of this study is obtain the comparison of the coeffisient of peformance (COP) and Energy Efficiency Ratio (EER) values in inverter split air conditioners with a capacity of 1/2 pk using R-22 and R-32 refrigerants. The method used in this study is observation and exsperiment , data collection based on test results using ac trainers that we make, using different refrigerants or refrigerants, namely R-22 and R-32 refrigerants, by varying the rotation of the evaporator fan in low, medium, and high modes. The results of this study are in the air conditioner (AC) split inverter capacity of 1/2 pk using R-22 refrigerant the highest coeffisient of peformance (COP) value obtained by 5.05 at the turn of the high evaporator fan and coeffisient of peformance (COP) in the air conditioner (AC) split inverter capacity of 1/2 pk using the highest R-32 refrigerant obtained by 7.37 in the high evaporator fan speed variant. Then the Energy Efficiency Ratio (EER) value produced in the air conditioner (AC) split inverter capacity of 1/2 pk using R-22 refrigerant is 17.22 Btu / h, while in the air conditioner (AC) split inverter capacity of 1/2 pk using R-32 refrigerant obtained 25.13 Btu / h. So that the performance of air conditioner (AC) split inverter capacity of 1/2 pk with refrigerant R-32 has better performance compared to air conditioner (AC) split inverter capacity of 1/2 pk with refrigerant R-22.
References
Ariyanto. (2015). Rancang Bangun Air Conditionimg Test-Bed (Desing of air conditioning test bed).
Firman.(2019).Refrigrasi dan Pengkondisan Udara. Makasar: Garis Putih Pratama.
Kusnandar. (2018). Analisa Performasi Mesin Pengkondisian Udara Menggunakan refrigerant R32. Seminar Nasional Penelitian Pengabdian Masyarakat, Universitas Bangka Belitung.
Kusnandar. (2019). Perbandingan COP AC Split kapasitas 1 pk menggunakan R410 dan R32 dengan variasi kecepatan fan evaporator. Jurnal Teknik Mesin, Universitas Tridinati Palembang. Desember 2019
Pita,Edward G. (2002). Air Conditioning Principle and system. Ohio: Prentice Hill.
Refrigeran – Komposisi Refrigeran – Sabtu,16Juli2022- https://www.polarin.com
Stoecker. (1989). Refrigeration and air conditioning. Jakarta: Erlangga.
Tentang AC - Evaporator Ac Daikin Pk – Sabtu,16Juli2022https://www.apklas.com
Widya Niko. (2018). Pembelajaran Teknik Pendingin. Malang: Lembaga Kajian Profesi.
Downloads
Published
Issue
Section
License
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).
Motor Bakar : Jurnal Teknik Mesin have CC BY-NC or an equivalent license as the optimal license for the publication, distribution, use, and reuse of scholarly work.
In developing strategy and setting priorities, Motor Bakar : Jurnal Teknik Mesin recognize that free access is better than priced access, libre access is better than free access, and libre under CC BY-NC or the equivalent is better than libre under more restrictive open licenses. We should achieve what we can when we can. We should not delay achieving free in order to achieve libre, and we should not stop with free when we can achieve libre.
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) License
YOU ARE FREE TO:
- Share — copy and redistribute the material in any medium or format
- Adapt — remix, transform, and build upon the material for any purpose, even commercially.
- The licensor cannot revoke these freedoms as long as you follow the license terms